Defence NSN Source is a one-stop shop for Circuit Breaker components and other similar products that meet the needs of our customer base. You have taken a specific interest in part number 5925PL1598690, a Inspektorat Wsparcia Sil Zbrojnych offering we carry that is listed alongside the NSN 5925-01-473-0635 to streamline identification and procurement. If you fill out and submit the Request for Quote (RFQ) form located below, you can secure pricing options for your comparisons. Within 15 minutes of one of our team members receiving and reviewing your submission, you can anticipate a customized response.
Note : We Will Not Share Your Information To Any Third Parties.
We strive to make the procurement process more straightforward and efficient by offering comprehensive details for listed components whenever possible. For instance, part number 5925PL1598690 was manufactured by Inspektorat Wsparcia Sil Zbrojnych under the CAGECode 9009H. Moreover, by using the first digits of the NSN 5925-01-473-0635, we can see that this product belongs to FSC 5925 Circuit Breakers. Utilizing such information, you can ensure that you are securing precisely what you need to carry out operations or meet your project requirements. Keeping this in mind, obtain a quote on part number 5925PL1598690 with our online services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-473-0635 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014730635 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
3126508 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AGAV | III END ITEM IDENTIFICATION | 2320-01-465-2174 |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 20.0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
ABTD | MOUNTING SLOT WIDTH | 0.210 INCHES NOMINAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
ABXD | BUSHING LENGTH | 0.120 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.820 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
TTQY | TERMINAL TYPE AND QUANTITY | 1 BUS BAR |
FEAT | SPECIAL FEATURES | PUSH TO RESET BUTTON |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 36.0 DC SINGLE LOCATION |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOT |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 20.0 DC SINGLE LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES DC SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
CXCY | III PART NAME ASSIGNED BY CONTROLLING AGENCY | CIRCUIT BREAKER, 20 AMP |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.350 INCHES NOMINAL |
AEBS | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER | 0.100 INCHES NOMINAL |
AAQL | BODY STYLE | SINGLE POLE TYPE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | RELAY TRIP SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
ADTV | CASE MATERIAL | PLASTIC |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS SINGLE LOCATION |