Defence NSN Source is a one-stop shop for Transformer Power components and other similar products that meet the needs of our customer base. You have taken a specific interest in part number SP314, a Edo Corp offering we carry that is listed alongside the NSN 5950-00-513-0922 to streamline identification and procurement. If you fill out and submit the Request for Quote (RFQ) form located below, you can secure pricing options for your comparisons. Within 15 minutes of one of our team members receiving and reviewing your submission, you can anticipate a customized response.
Note : We Will Not Share Your Information To Any Third Parties.
We strive to make the procurement process more straightforward and efficient by offering comprehensive details for listed components whenever possible. For instance, part number SP314 was manufactured by Edo Corp under the CAGECode 09017. Moreover, by using the first digits of the NSN 5950-00-513-0922, we can see that this product belongs to FSC 5950 Coils and Transformers. Utilizing such information, you can ensure that you are securing precisely what you need to carry out operations or meet your project requirements. Keeping this in mind, obtain a quote on part number SP314 with our online services.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-513-0922 Item PartTypeName: TRANSFORMER,POWER | 5950 | 005130922 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
SP314 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.844 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 4.906 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.969 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.031 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 5.625 INCHES MINIMUM AND 5.875 INCHES MAXIMUM |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO TWO PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | SCOTT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 5.750 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.875 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED WITH OIL |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 7.7 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2.45 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 24.89 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2.45 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 30.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY24.89 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2.45 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 90.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY30.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY24.89 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | EXTERNAL JUMPER REQUIRED FOR SUGGESTED SCOTT-T OPERATION |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 14 TURRET |