MRC | Criteria | Characteristic |
---|
AAJD | THREAD CLASS | 2B SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 2.907 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.500 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.500 INCHES NOMINAL |
ABNB | FIRST FLAT LENGTH | 0.438 INCHES NOMINAL SINGLE ACTUATOR |
ABNC | FLAT HEIGHT | 0.219 INCHES NOMINAL SINGLE ACTUATOR |
ABWV | SHAFT DIAMETER | 0.250 INCHES NOMINAL SINGLE ACTUATOR |
ABXF | SHAFT LENGTH | 0.688 INCHES NOMINAL SINGLE ACTUATOR |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.312 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AFBH | INDIVIDUAL SECTION QUANTITY | 4 |
AFCQ | KNOB MANUFACTURER CODE | 82121 |
AFCY | KNOB MANUFACTURER PART NUMBER | A |
AJZE | SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
AKPX | POLE QUANTITY | 1 EACH SECTION FRONT |
AKPY | THROW QUANTITY | 3 EACH SECTION FRONT |
ALAQ | MOUNTING FACILITY CIRCLE RADIUS | 0.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AXGY | MOUNTING METHOD | BRACKET SINGLE MOUNTING FACILITY |
CBBL | FEATURES PROVIDED | ACTUATOR KNOB |
CMLP | THREAD QUANTITY PER INCH | 24 SINGLE MOUNTING FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE MOUNTING FACILITY |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 120.0 LOWEST AC VOLTAGE RATING AT SEA LEVEL |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 125.0 LOWEST DC VOLTAGE RATING AT SEA LEVEL |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 250.0 HIGHEST DC VOLTAGE RATING AT SEA LEVEL |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 450.0 HIGHEST AC VOLTAGE RATING AT SEA LEVEL |
CQYJ | MOUNTING FACILITY PATTERN | FOUR POSITION CIRCULAR SINGLE MOUNTING FACILITY |
CRJH | SWITCH ACTUATOR INDEXING POSITION QUANTITY | 3 SINGLE ACTUATOR |
CRSJ | SHAFT TYPE | ROUND,FLATTED,THREADED HOLE SINGLE ACTUATOR |
CSCF | TERMINAL TYPE | TAB W/SCREW |
CSHW | CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES EACH SECTION FRONT |
CSLC | SWITCH ACTUATOR POSITIONING INCREMENT | 90.0 DEGREES SINGLE ACTUATOR |
CTDN | SWITCH ACTUATOR STOP DEVICE TYPE | FIXED STOP SINGLE ACTUATOR |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD HIGHEST AC VOLTAGE RATING AT SEA LEVEL |
CTHF | CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD LOWEST AC VOLTAGE RATING AT SEA LEVEL |
CTHF | CONTACT LOAD CURRENT RATING | 3.0 AMPERES RESISTIVE LOAD LOWEST DC VOLTAGE RATING AT SEA LEVEL |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD HIGHEST DC VOLTAGE RATING AT SEA LEVEL |
STYL | STYLE DESIGNATOR | TAP,CIRCUIT SELECTOR |
TEST | TEST DATA DOCUMENT | 89661-54B7064H02 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING D |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |